Forum für Wissenschaft, Industrie und Wirtschaft

Hauptsponsoren:     Siemens  n-tv 
Datenbankrecherche:

Fachgebiet (optional):

 

A better sign of blood vessel narrowing and early coronary artery disease

04.02.2010
Major study of perfusion imaging under way to assess value of alternative diagnostic methods

Anzeige

Cardiologists and heart imaging specialists at 15 medical centers in eight countries, and led by researchers at Johns Hopkins, have enrolled the first dozen patients in a year-long investigation to learn whether the subtle squeezing of blood flow through the inner layers of the heart is better than traditional SPECT nuclear imaging tests and other diagnostic radiology procedures for accurately tracking the earliest signs of coronary artery clogs.


Each year, nearly 800,000 American men and women with coronary artery disease suffer a heart attack, resulting in more than 150,000 deaths.

The latest international study of so-called CT perfusion imaging will involve the participation of some 400 men and women identified as being at higher risk of coronary artery disease because they have had symptoms of the illness, such as shortness of breath, chest pain or fatigue. All qualify for a more detailed inspection of their heart’s blood vessels by cardiac catheterization, an invasive procedure in which a thin plastic tube is directly inserted into the heart’s blood vessels to detect blockages and help widen each artery as needed.

“Our study goal is to figure out how well various imaging tests measure the degree of blockage or narrowing in any particular artery and therefore which is more useful in predicting patients who need catheterization or angioplasty, or bypass surgery,” says cardiologist and senior study investigator João Lima, M.D. “Some patients would do just as well or better with drug therapy to maintain a healthy blood flow to the heart, but we need to better sort out who they are with more accuracy.”

Lima says that as many as one-fifth of the 1.3 million cardiac catheterizations performed each year nationwide show no blockages.

In addition to having a standard SPECT imaging test, in which radioactive chemicals are injected into the body to produce 3-D images of the blood vessels, all study participants will undergo before catheterization another test to map out the blood vessels and any potential blockages, a CT angiogram (CTA), plus a CT perfusion (CTP) imaging test to gauge any changes in the volume of blood flow.

Key to performing both CTA and CTP is use of the 320 computed tomography scanner, the most advanced technology available to image the heart and its surrounding blood vessels. The device was first installed in North America at Johns Hopkins in 2007 and can produce three-D images of blood vessels no bigger than the average width of a toothpick (1.5 millimeters). Results from both 320-CT tests will be compared to those from SPECT and what is found by cardiac catheterization.

“Perfusion imaging is a simple and easy test for patients to undergo,” says Lima, who adds that the whole procedure usually takes less than 20 minutes to set up and perform. Cardiac catheterization, which also checks for heart vessel blockages, takes longer, between 30 minutes and 45 minutes to perform, and requires several hours for recovery. Potential complications from the invasive procedure, although rare, include heart attack, stroke and death.

“If we can more easily examine patients, then we can reduce the amount of time needed in hospital and, we hope, reduce the number of invasive procedures, which are more inconvenient and open to greater risk to patients from complications,” says Lima, a professor of medicine and radiology at the Johns Hopkins University School of Medicine and its Heart and Vascular Institute.

More than a quarter-million Americans undergo coronary bypass surgery each year, and another 1.2 million people undergo angioplasty, a procedure much like catheterization that forcibly opens narrowed arteries.

Lead study investigator and cardiologist Richard George, M.D., part of the Johns Hopkins team that developed special computer software to accurately measure the speed of blood flowing through the heart’s arteries and muscle, says the 320-CT is fast and exposes patients to far less radiation.

George, an assistant professor at Hopkins where he also serves as director of its CT Perfusion Laboratory, says a CTP takes three seconds or less of actual scanning and, if done correctly, involves an average radiation exposure of about 8 millisieverts. A SPECT test, he says, averages between 10 millisieverts and 26 millisieverts, and cardiac catheterization ranges between 2 millisieverts and 10 millisieverts. The 320-CT scanning device has at least five times the speed and power of the 64-CT scanners in widespread use elsewhere.

The scanner’s software compares ratios of brightly dyed blood flows between the innermost and outermost layers of heart muscle, where the effects of arterial narrowing first appear.

As part of CTP imaging, each patient is injected with a chemical dye containing iodine, known to light up on screen when struck by the scanner’s X-rays. Lower concentrations of iodine will show up as darker regions, indicating constrained and reduced blood flow, the underlying cause of chest pain, than brighter regions where blood flow is more uniform and free flowing.

To enhance the image, blood flow to the heart is sped up through chemical injections of adenosine, which causes the blood-pumping organ to beat faster.

Previous research by the team among 60 patients with suspected coronary artery disease showed that using dual testing with CTA and CTP had almost the same statistical predictive values as SPECT, prompting the team’s latest investigation to see if the dual tests were as clinically useful as SPECT.

George cautions that CT scans are not a substitute for catheterization, but are “an alternative diagnostic tool” physicians can use to “get a real picture” of the extent of coronary blockages and their effects on blood flow, especially when physicians need both sets of information to make treatment decisions.

The CT device being used in the study is an Aquilion One, a 320 detector row CT scanner manufactured by Toshiba.

Toshiba also provided funding support for the study, called CORE-320, short for Coronary Artery Evaluation Using 320-row Multidetector Computed Tomography.

The CORE-320 study follows another imaging study, called CORE-64, which showed that 64-CT was almost as good as cardiac catheterizations in predicting which patients with suspected coronary disease actually had coronary blockages.

In addition to Lima and George, other Hopkins researchers involved in this study are Armin Arbab-Zadeh, M.D.; Julie Miller, M.D.; Jeffrey Brinker, M.D.; David Bluemke, M.D.; Andrea Vavere, M.S.; John Texter, P.A.; Albert Lardo, Ph.D.; Eric Bukata; and Christopher Cox, Ph.D.

Other CORE-320 participating sites include in the United States, Beth Israel Deaconess Medical Center and the Brigham and Women’s Hospital, both in Boston, plus the U.S. National Heart, Lung and Blood Institute, a member of the National Institutes of Health, in Bethesda, Md.; in Canada, Toronto General Hospital, part of the University Health Network; in Denmark, the Rigshospitalet at the University of Copenhagen; in Germany, Charité Universitätsmedizin in Berlin; in the Netherlands, Leiden University Medical Center; in Brazil, the Heart Institute of the Clinical Hospital of Sao Paulo University’s Medical College in Botucatu, and the Hospital Israelita Albert Einstein in Sao Paulo; in Singapore, Medi-Rad Associates Radiologic Clinic at Mount Elizabeth Medical Centre, and the National Heart Centre Singapore; and in Japan, Iwate Medical University in Morioka, Mie University School of Medicine in Tsu City, and Keio University’s School of Medicine in Tokyo.

For additional information, please go to:

Sample images of the heart and its blood vessels as scanned by the 320-CT are available for viewing at:
http://www.hopkinsmedicine.org/Press_releases/2007/11_26_07.html

Media contact: David March
410-955-1534 office; dmarch1@jhmi.edu

David March | Quelle: EurekAlert!
Weitere Informationen: www.jhmi.edu

Weitere Nachrichten aus der Kategorie Studien Analysen:

nachricht Wandel der Hochschulbildung in Deutschland und Professionalisierung
09.02.2012 | Institut für Hochschulforschung (HoF) an der Martin-Luther-Universität Halle-Wittenberg

nachricht Internet-Therapie hilft bei quälendem Tinnitus
09.02.2012 | Johannes Gutenberg-Universität Mainz

Alle Nachrichten aus der Kategorie Studien Analysen >>>

Die aktuellsten Pressemeldungen zum Suchbegriff Innovation >>>


Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Wissenschaftler machen Eisen durchsichtig


Erstmals gezeigt, dass Atomkerne transparent werden

Einem Team von DESY-Wissenschaftlern um Dr. Ralf Röhlsberger gelang es an der hochbrillanten Synchrotronlichtquelle PETRA III, Atomkerne mit Hilfe von Röntgenlicht transparent zu machen. Sie entdeckten dabei gleichzeitig ein neues Prinzip, um einen optisch gesteuerten Schalter für Licht herzustellen, also Licht mit Licht zu beeinflussen, ein wichtiger Baustein auf dem ...

Im Focus: Anti-Angst-Hormon Oxytocin wird gezielt an seine Wirkorte im Gehirn transportiert


Wissenschaftler beobachten, wie Oxytocin zentrale Schaltstellen im Gehirn erreicht und das Verhalten beeinflusst

Kuschelhormon, Treuehormon, Angstlöser – häufig gebrauchte Schlagwörter für das Neuropeptid Oxytocin, das sich in den letzten Jahren als ein Stoff erwiesen hat, der unser Verhalten in zentralen Regionen des Gehirns positiv beeinflussen kann. Was jedoch bisher völlig unklar war: Wie gelangt dieser Botenstoff aus dem Hypothalamus in die Hirnbereiche, die ...

Im Focus: Datenspeicher mit Lachs-DNA und Nano-Silber


Ein neuartiger Biopolymer-Film aus Lachs-DNA mit Silber-Nanopartikeln speichert Informationen kostengünstig und umweltverträglich.

Entstanden ist das organische System in fächer- und länderübergreifender Zusammenarbeit von Wissenschaftlern des DFG-Centers for Functional Nanostructures (CFN) am KIT und des Institute of Photonics Technologies an der National Tsing Hua University in Taiwan. Der DNA-Datenspeicher eignet sich unter anderem für biotechnische Anwendungen, etwa als Bauteil in Biosensoren.

Das System ...

Im Focus: VLT liefert detailreichstes Infrarotbild des Carinanebels


Bildveröffentlichung der Europäischen Südsternwarte (Garching) - Mit dem Very Large Telescope (VLT) der ESO haben das bislang detailreichste Infrarotbild der Sternkinderstube des Carinanebels aufgenommen. Es zeigt vor dem spektakulären Hintergrund einer himmlischen Landschaft auf Gas, Staub und jungen Sterne zahlreiche nie gesehene Details und zählt zu den atemberaubendsten VLT-Bildern überhaupt.

Im Herzen der südlichen Milchstraße, im Sternbild Carina (Der Schiffskiel, [1]), befindet sich in einer Entfernung von etwa 7500 Lichtjahren die Sternkinderstube des Carinanebels. Diese ausgedehnte Wolke aus leuchtendem Gas und Staub ist von der Erde aus gesehen eine der nächstgelegenen Geburtsstätten massereicher Sterne.

Der Nebel beinhaltet einige der hellsten und ...

Im Focus: Automatisch Lücken im Funkspektrum erkennen


Auf der embedded world identifizieren Wissenschaftler der Fraunhofer ESK Lücken im Funkspektrum, um diese für zusätzliche Übertragungen zu nutzen.

Der in Halle 5, Stand 5-228, vorgestellte Prototyp zeigt das Funkspektrum in einem 3D-Spektrogramm, markiert die prognostizierten Lücken und prüft deren Eintreffen. Diese Methode, Cognitive Radio, verbessert die Übertragungsqualität in einem bereits vollen Funkspektrum ohne aufwändiges, statisches Koexistenzmanagement. Ziel ist eine höhere Verfügbarkeit und Zuverlässigkeit von Funk für die Automatisierung.
...

Alle Focus-News des innovations-reports >>>

Anzeige

B2B Suche
Produkt / Dienstleistung
Firma / Organisation

Anzeige

IHR
JOB & KARRIERE
SERVICE
im innovations-report
in Kooperation mit academics
Aktuell

Kaltwasserkorallen als Anpassungskünstler?

09.02.2012 | Ökologie Umwelt- Naturschutz

Wandel der Hochschulbildung in Deutschland und Professionalisierung

09.02.2012 | Studien Analysen

Ocean warming causes elephant seals to dive deeper

09.02.2012 | Biowissenschaften Chemie

VideoLinks
B2B-VideoLinks
Weitere VideoLinks >>>
Veranstaltungen

7. Mannheimer Arbeitsrechtstag am 14. März mit Experten aus Theorie und Praxis

09.02.2012 | Veranstaltungsnachrichten

International Forum on Terahertz Spectroscopy and Imaging

09.02.2012 | Veranstaltungsnachrichten

Teams aus neun Ländern treffen sich an der Leibniz Universität zum 6th Hanover PreMoot

09.02.2012 | Veranstaltungsnachrichten

FindAndHelp