Instead, that electricity must be used for cooling the servers, a demand that continues to increase as computer processing power grows.
And the trend toward cloud computing will expand the need for both servers and cooling.
At the Georgia Institute of Technology, researchers are using a 1,100-square-foot simulated data center to optimize cooling strategies and develop new heat transfer models that can be used by the designers of future facilities and equipment. The goal is to reduce the portion of electricity used to cool data center equipment by as much as 15 percent.
“Computers convert electricity to heat as they operate,” said Yogendra Joshi, a professor in Georgia Tech’s Woodruff School of Mechanical Engineering. “As they switch on and off, transistors produce heat, and all of that heat must be ultimately transferred to the environment. If you are looking at a few computers, the heat produced is not that much. But data centers generate heat at the rate of tens of megawatts that must be removed.”
Summaries of the research have been published in the Journal of Electronic Packaging and International Journal of Heat and Mass Transfer and presented at the Second International Conference on Thermal Issues in Emerging Technologies, Theory and Applications. The research has been sponsored by the U.S. Office of Naval Research, and by the Consortium for Energy Efficient Thermal Management.
Five years ago, a typical refrigerator-sized server cabinet produced about one to five kilowatts of heat. Today, high-performance computing cabinets of about the same size produce as much as 28 kilowatts, and machines already planned for production will produce twice as much.
“Some people have called this the Moore’s Law of data centers,” observed Joshi, who is also the John M. McKenney and Warren D. Shiver Chair in the School of Mechanical Engineering. “The growth of cooling requirements parallels the growth of computing power, which roughly doubles every 18 months. That has brought the energy requirements of data centers into the forefront.”
Most existing data centers rely on large air conditioning systems that pump cool air to server racks. Data centers have traditionally used raised floors to allow space for circulating air beneath the equipment, but cooling can also come from the ceilings. As cooling demands have increased, data center designers have developed complex systems of alternating cooling outlets and hot air returns throughout the facilities.
“How these are arranged is very important to how much cooling power will be required,” Joshi said. “There are ways to rearrange equipment within data centers to promote better air flow and greater energy efficiency, and we are exploring ways to improve those.”
Before long, centers will likely have to use liquid cooling to replace chilled air in certain high-powered machines. That will introduce a new level of complexity for the data centers, and create differential cooling needs that will have to be accounted for in the design and maintenance.
Joshi and his students have assembled a small high-power-density data center on the Georgia Tech campus that includes different types of cooling systems, partitions to change room volumes and both real and simulated server racks. They use fog generators and lasers to visualize air flow patterns, infrared sensors to quantify heat, airflow sensors to measure the output of fans and other systems, and sophisticated thermometers to measure temperatures on server motherboards.
Beyond studying the effects of alternate airflow patterns, they are also verifying that cooling systems are doing what they’re supposed to do.
Because tasks are dynamically assigned to specific machines, heat generation varies in a data center. Joshi’s group is also exploring algorithms that could help even out the computing load by assigning new computationally-intensive tasks to cooler machines, avoiding hot spots.
Another issue they’re studying is what happens when utility-system power to a data center is cut off. The servers themselves continue to operate because they receive electricity from an uninterruptible power supply. But the cooling equipment is powered by backup generators, which can take minutes to get up to speed.
During the brief time without cooling, heat builds up in the servers. Existing computer models predict that temperatures will reach dangerous levels in a matter of seconds, but actual measurements done by Joshi’s graduate students show that the equipment can run for as much as six minutes without cooling.
“We’re developing models for different parts of the data center to learn how they respond to changes in temperature,” said Shawn Shields, a former graduate student in Joshi’s lab. “Existing models consider that temperature changes across a server rack will be instantaneous, but we’ve found that it takes quite a relatively long time for the server to reach a steady state.”
Beyond reducing cooling load, the researchers are also looking at how waste heat from data centers can be used. The problem is that the heat is at relatively low temperatures, which makes it inefficient to convert to other forms of energy. Options may include heating nearby buildings or pre-heating water, Joshi said.
Data obtained by the researchers with thermometers and airflow meters is being used to validate computer models that are reasonably accurate, but run rapidly. In the future, these models will help data center operators do a better job of optimizing cooling in real time, he said.
Joshi believes there’s potential to reduce data center energy consumption by as much as 15 percent by adopting more efficient cooling techniques like those under development in his lab.
“Our data center laboratory is a complete sandbox in which we can study all sorts of options without affecting anybody’s computing projects,” he added. “We can look at interesting ways to improve rack-level cooling, liquid cooling and thermoelectric cooling.”
John Toon | Quelle: Newswise Science News
Weitere Informationen: www.gatech.edu
Weitere Berichte zu: computer model > cooling strategies > cooling system > Data Centers > Energy Efficient Thermal Management > Ferchau Engineering > Heat Blanket > Mechanical Engineering
„All4Green“ – Rechnen, wenn der Wind bläst
24.05.2012 | Universität Mannheim
Komplexität beherrschen
23.05.2012 | Siemens AG
Krankheiten wie Parkinson, Alzheimer und bestimmte Krebsformen gehen auf eine fehlerhafte Faltung und Aggregation von Eiweißen im Körper zurück.
Wissenschaftlern des Instituts für Photonische Technologien (IPHT) in Jena ist es erstmals gelungen, Proteinstrukturen auf sub-molekularer Ebene nachzuweisen und spektroskopisch zu analysieren. Ein wichtiger Schritt zum Verständnis der Krankheitsursachen.
„Bis heute hat man nicht genau verstanden, was die fehlerhafte Faltung und Aggregation von Eiweißen, zum Beispiel im Zusammenhang mit Alzheimer, ...
Die Quantenphysik beschreibt physikalische Vorgänge in Festkörpern und anderen Vielteilchensystemen auch mit Hilfe von Quasiteilchen.
Innsbrucker Physikern um Rudolf Grimm ist es nun erstmals gelungen, ein neues Quasiteilchen - ein repulsives Polaron - in einem Quantengas experimentell zu erzeugen. Die Forscher berichten darüber in der Online-Ausgabe der Fachzeitschrift Nature.
Ultrakalte Quantengase sind ein ideales Experimentierfeld, um physikalische Phänomene in Festkörpern zu simulieren. Unter streng kontrollierten Bedingungen ...
Licht lässt die Partikel in der Atmosphäre wachsen. In einem Experiment hat ein internationales Forscherteam erstmals einen neuen Mechanismus nachweisen können, bei dem Partikel durch Licht größer werden und der damit Einfluss auf die Wolkenbildung und das Klima hat.
Photokatalytische Reaktionen können zu einer schnellen Bindung von nicht kondensierenden flüchtigen organischen Kohlenwasserstoffen (VOCs) auf der Oberfläche der Partikel führen. Unter solchen Bedingungen nehme die Größe und Masse der Partikel schnell zu, schreiben die Wissenschaftler im renommierten Fachblatt PNAS.
Die Ergebnisse des Laborexperimentes könnten Effekte erklären, die bisher schon bei Feldkampagnen ...
Ähnlich wie blutsaugende Insekten prüfen Pflanzenschädlinge ihren Wirt auf Abwehrsignale, bevor sie anfangen zu fressen
Pflanzen bilden wenige Minuten nach Angriff eines Fraßfeindes Jasmonsäure, ein Hormon, das die Verteidigung gegen Insekten in Gange setzt mit der Folge, dass giftige Stoffe wie Nikotin oder Verdauungshemmer in den Blättern akkumulieren.
Wissenschaftler des Max-Planck-Instituts für chemische Ökologie, Jena, haben jetzt herausgefunden, dass Zwergzikaden die Verteidigungsbereitschaft von Tabakpflanzen aufspüren können. ...
Wissenschaftlern vom Institut für Physikalische und Theoretische Chemie der Universität Bonn ist es erstmals gelungen, den Transport eines wichtigen Informationsträgers in biologischen Zellen praktisch unmodifiziert in Echtzeit zu filmen.
Die Studie zeigt, wie die so genannte Boten-RNA die Zellkernhülle überwindet und vom Zellkern in das Zytoplasma gelangt. Diese Arbeit ist nun in dem renommierten Journal „Proceedings of the National Academy of Sciences of the USA“ (PNAS) publiziert.
Der Bauplan aller Lebewesen ist in ihrem Erbgut gespeichert. Dieses lagert bei höheren ...
Anzeige
Anzeige

Energieversorger vor dem Umbruch
24.05.2012 | Studien Analysen
Stem-cell-growing surface enables bone repair
24.05.2012 | Biowissenschaften Chemie
Im wahrsten Sinne „Spitzenforschung“: IPHT-Forscher untersuchen Eiweißfasern mit größter Genauigkeit
24.05.2012 | Biowissenschaften Chemie
NieKE Themenforum: Ökonomie - Tierschutz - Lebensmittelsicherheit
24.05.2012 | Veranstaltungsnachrichten
Nachhaltigkeit in der Schifffahrt: Werte vs. Wertschöpfung
24.05.2012 | Veranstaltungsnachrichten
Wissenschaft und Öffentlichkeit
24.05.2012 | Veranstaltungsnachrichten